Pur-MAXX E-SG

Dual Layer Pleated Polyethersulfone Membrane Sterilizing Grade Cartridge

Pur-MAXX E-SG Dual Layer Pleated Polyethersulfone Membrane Sterilizing Grade Cartridge

Download PDF

The Pur-MAXX E-SG is engineered to meet the highest standards of microorganism control for sterile fluids. Pur-Maxx E-SG filter element is validated for complete removal of Brevundimonas diminuta (ATCC 19146) at test concentrations of 107 CFU/cm2 (Colony Forming Units). This product is ideally suited for applications where microorganism contamination causes product defects or extra processing time due to increase fluid instability.

Pur-Maxx E-SG is produced utilizing a unique multi-pleated configuration integrating highly asymmetric and hydrophillic polyethersulfone membrane with exceptional pleat support materials. This novel multi-pleated approach increases cartridge life, strength and durability. This structural product enhancement allows our filter cartridges to withstand multiple sterilization cycles without sacrificing product integrity.

This Sterilizing Grade pleated cartridge complies with FDA CFR Title 21 and USP Biological Reactivity for Class VI Plastics. By combining these ultra pure components with the low protein binding features of highly asymmetric hydrophillic polyethersulfone membrane makes Pur-Maxx E-SG perfect for applications in the biopharmaceutical, and bottled water industries.

Typical Applications

Final filtration of:

  • WFI & CIP Water
  • Cell Culture Purification
  • Buffer Solutions
  • Vaccines
  • Diagnostics
  • LVP (Large Volume Parenterals)
  • Features and Benefits
  • Specifications
  • Ordering Information
  • End Cap Configurations
  • Validated 0.2 μm absoluted rated membrane configuration High surface area membrane offers excellent life and flux rates while providing absolute filtration
  • Absolute-rated dual layer membrane provides reliable, consistent and repeatable filtrate quality
  • Low pressure drops yield higher flow rates and reduced processing time
  • Non-fiber shedding Polypropylene support materials eliminate fiber migration
  • MAXX-imum Pleat Design for greater surface area, ensuring longer service life, fewer changeouts and reduced operating costs per element
  • All materials of construction are FDA compliant with CFR Title 21 and are bio-safe in accordance with USP Class VI
  • 100% Thermally bonded construction
  • Low hold-up volumes
  • Integrity tested
  • High strength design allowing for extended use and multi autoclave and hot water sanitization cycles
  • 316 SS reinforced end treatments
Materials of Construction
Filter Media: Polyethersulfone
Support Material: Polypropylene
End Caps: Polypropylene
Reinforcing Ring: 316 Stainless Steel
Cage/Core: Polypropylene
Sealing: Thermal Bond
Seals: Buna N, Fluorocarbon, EPDM, Silicone
Dimensions
Outside Dia: 2.7" (6.87cm)
Lengths: 10" (25.4cm), 20" (50.8cm),
30" (76.2cm), 40" (102cm)
Effective Filtration Area: 7 ft.2 (0.65m2)
Performance Specification
Absolute Rated Retention: 0.20 μm
Maximum Forward Differential Pressure
Forward: 75 psid (5.5 bar) @ 75°F (24°C)
40 psid (2.8 bar) @ 180°F (82°C)
Reverse: 50 psid (3.4 bar) @ 75°F (24°C)
Maximum operating Temperature
180°F (82°C) Continuous Duty
Toxicity
Cartridge materials meet USP Class VI and CFR 21 for food and beverage contact
Sterilization
Cartridge can be sterilized via steam or Autoclave:
20 times at 275°F (135°C) Cartridge may be sanitized in place with common sanitizing agents, contact factory for chemical compatibility
Packaging Economy
Bulk packaging in case quantities to reduce material disposal
10 inch 24 per carton
20 inch 12 per carton
30 inch 12 per carton
40 inch 9 per carton
Integrity Test Values
Pore Size Bubble Point Test Pressure Air Diffusion
PRMXE0.2-SG 22psig 17psig* ≤10mL/min
*50/50 IPA/DI water solution
USP Physicochemical Tests for Plastics
Ultrapure water extracts from multiple lots of PUR-Maxx E-SG cartridges were tested and shown to have values that comply with USP limits.
Test Results USP Limit
Non volatile residue <2mg <15mg
Heavy Metals <1ppm <1ppm
Residue on Ignition <2mg <5mg
Buffering Capacity <1mL <10mL
Cartridge Series Micron
Rating
Length Support Materials End Cap Configurations Gasket/O-Ring Materials Cartridge Grade
ex. PRMXE Pur-MAXX E 0.2 0.20 -10 10 20 30 40 PP PP - Polypropylene C7 C3-SOE flat closed ends, external 222 O-ring C6-SOE flat closed end, external 226 O-ring C7-SOE fin end, external 226 O-ring C8-SOE fin end, external 222 O-ring S S - Silicone (standard O-rings) B - Buna N (standard gaskets) V - Fluorocarbon E - EPDM SG SG- Steralizing Grade

C1- DOE flat open ends

C2- SOE recessed cup, internal 213 o-ring

C3-SOE flat closed ends, external 222 o-ring

C5-SOE recessed cup, external 222 o-ring

C6-SOE flat closed end, external 226 o-ring

C7-SOE fin end, external 226 o-ring

C8-SOE fin end, external 222 o-ring